Validic (RPGHD)
1.0.0 - release

Validic (RPGHD) - Local Development build (v1.0.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Artifacts Summary

This page provides a list of the FHIR artifacts defined as part of this implementation guide.

Structures: Resource Profiles

These define constraints on FHIR resources for systems conforming to this implementation guide.

VA Validic BMI object

BMI object observation from Validic

VA Validic Blood Glucose object

Blood Glucose object observation from Validic

VA Validic Blood Pressure object

Blood Pressure object observation from Validic with 2 component(s)

VA Validic Body Arms object

Body Arms object observation from Validic

VA Validic Body Chest object

Body Chest object observation from Validic

VA Validic Body Fat object

Body Fat object observation from Validic

VA Validic Body Height object

Body Height object observation from Validic

VA Validic Body Hips object

Body Hips object observation from Validic

VA Validic Body Temperature object

Body Temperature object observation from Validic

VA Validic Body Thighs object

Body Thighs object observation from Validic

VA Validic Body Waist object

Body Waist object observation from Validic

VA Validic Body Weight object

Body Weight object observation from Validic

VA Validic CGM Summary object

CGM Summary object observation from Validic with 14 component(s)

VA Validic Daily Activity Summary object

Daily Activity Summary object observation from Validic with 21 component(s)

VA Validic Device Definition object

Device Definition object from Validic

VA Validic FEF-25-75 object

FEF-25-75 object observation from Validic

VA Validic FET object

FET object observation from Validic

VA Validic FEV1 object

FEV1 object observation from Validic

VA Validic FEV1/FVC object

FEV1/FVC object observation from Validic

VA Validic HFD Blood Glucose object

HFD Blood Glucose object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic HFD Distance object

HFD Distance object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic HFD Elevation object

HFD Elevation object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic HFD Heart Rate object

HFD Heart Rate object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic HFD SpO2 object

HFD SpO2 object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic HFD Steps object

HFD Steps object observation from Validic. Uses component with valueSampledData for high-frequency time-series readings.

VA Validic Insulin object

Insulin object observation from Validic

VA Validic Nutrition Summary object

Nutrition Summary object observation from Validic with 12 component(s)

VA Validic Observation Base Profile

Base profile for VA Validic patient-generated health data observations. Extends VA PGHD governance base to inherit required invariants (pghd-meta-tag-1, pghd-observation-status-1, pghd-observation-codesystem-1). Adds Validic-specific source tracking tags and device reference.

VA Validic PEF object

PEF object observation from Validic

VA Validic Patient object

Patient object from Validic

VA Validic Pulse/Heart Rate object

Pulse/Heart Rate object observation from Validic

VA Validic Sleep Summary object

Sleep Summary object observation from Validic with 11 component(s)

VA Validic SpO2 object

SpO2 object observation from Validic

VA Validic Workout Summary object

Workout Summary object observation from Validic with 19 component(s)